Recommended configuration | ||
Robot & Pipettes Equipment and Pipettors | Opentrons Flex Automated Pipe Workstation | |
Flex Gripper Transfer Gripper | ||
Single-channel pipette (1-50 μL) + 8-channel pipette (5-1000 μL) / 8-channel pipette (1-50 μL) + 8-channel pipette (5-1000 μL) / 96-channel pipette (1-200 μL) | ||
Modules module configuration | Temperature control module | |
Thermal oscillation module | ||
Ring magnetic rack (optional) | ||
Thermal cycling module (optional) | ||
Positive pressure module/centrifuge (optional) | ||
Plate absorbance reader (optional) | ||
Automation stack module (optional) | ||
HEPA/UV module (optional) | ||
Optional add-ons | External garbage trough | |
Expansion board position (1-4) |
关于Opentrons Flex、OT-2产品的常见问题,Please click here.
Do you need to know programming knowledge with Opentrons Flex?
Using the Opentrons platform does not require programming knowledge. You can create protocols using Opentrons' concise and easy-to-understand protocol design tools. In addition, our application engineering technology team can also build custom protocols for you.
What services can you enjoy when purchasing Opentrons Flex?
On-site installation, remote service and annual preventive maintenance.
What kind of laboratory utensils are Opentrons Flex compatible?
与OT-2一样,Flex可以支持任何与自动化兼容、符合ANSI/SLAS标准的孔板,以及种类繁多的EP管和螺帽离心管,包括容积达50 mL的离心管。您可以在我们的Laboratory instrument library中查看所有受支持的实验室器具。
Do I need a computer to connect to Opentrons Flex? Or can I operate it directly on the touch screen?
Users do not need to connect to the computer to run the protocol. After completing the protocol creation on your computer, upload it to Flex, which can be operated through the touch screen.
Can an OT-2 pipette be used on Opentrons Flex?
No, the OT-2 pipette does not fit Opentrons Flex.
Is the Opentrons Flex side panel removable?
Yes, the side windows and front doors of the Opentrons Flex are removable.
Does Opentrons Flex have collision detection function?
Opentrons Flex will detect collisions by comparing the actual movement of the embedded motor with the expected movement. For example, if the robot expects to perform 2 motor rotations, but only 1 rotation is completed due to a collision (stop motor movement) the robot will detect the difference between the expected movement and the actual movement. Then an error message will appear telling you that you need to recalibrate.
Can I control multiple Opentrons Flexes with one computer?
Can! The same applies to OT-2.
How many saved protocols can be displayed on Opentrons Flex?
Users can save up to 8 protocols on the Opentrons Flex touch screen.
What is the gap between the rear space of the Opentrons Flex for power and ventilation?
20 cm (8 inches) side and back clearance for cable, USB connection, and dissipate exhaust from instruments such as thermal cycle modules or temperature control modules.
Welcome to make an appointment for an online demonstration to discuss your experimental needs with a professional team of applied scientists.
Make an appointment for a demoThe experienced service team and strong production support team provide customers with worry-free order services.